Printronix P5000 Technical Bulletins | theprinterplace.com
 
 

 

 
 
 
 
 
 
 
 

Printronix P5000 Printer Technical Note 5-0037 Rev A

Reminder to Check Connector Keys on CMX/CFX PCBAs

Summary: 

This Technical Bulletin has been written as a reminder on how important it is to note the proper
orientation of the power cables as they are reinstalled during the course of normal troubleshooting
and/or replacement of that assembly.

Resolution:

The cables that would be affected the most by a mis-orientation of the connector where pin 1

marked on the connector does not line up correctly with pin 1 silk- screened on both the CMX and

CFX PCBAs are:

P101 - Power Cable Connector Assy (part of Power Supply) to J101 on board.

P102 - +5V Remote Power Cable Assy (154364-001) to J102 on board.

P105 - Hammer Bank Power Cable Assy (152423-001) to J105 on board.

P116 – Shuttle Motor Drive Cable Assy (152420-001) to J116 on board.

Important

Failure to mate the connectors correctly may result in damage to the printer and/or unpredictable

behavior.

 

Need help? Call our knowledgeable sales staff at: 1-800-243-3338


ThePrinterPlace has taken care to ensure that the information is complete, accurate and up-to-date. However, ThePrinterPlace assumes no responsibility for errors or omissions which may occur. This information is provided "as is" without warranty of any kind. All procedures should be completed by a factory authorized technician. ThePrinterPlace disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall ThePrinterPlace be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages. All trademarks are property of their respective holders